General Lighting Information
Buildings.com
Daylighting Collaborative
Heschong Mahone Group
Illuminating Engineering Society of North America
Independent Electrical Contractors
Lighting Research Center
Municipal Solid State Street Lighting Consortium
National Association of Electrical Distributors
National Association of Independent Lighting Distributors
National Council on Qualifications for the Lighting Professions
National Electrical Contractors Association
National Lighting Bureau
New Buildings
U.S. DOE Office of Building
LED Lighting Publications
Lighting Manufacturer Resources
National Electrical Manufacturers Association
National Electrical Manufacturers Representatives Association
Lighting Design Resources
International Association of Lighting Designers
Lighting Design Lab
Solid State Lighting Design
CB网址:
IECEE 的网址:http://www.iecee.org/html/AboutIECEE.htm
OD:Operating document:http://www.iecee.org/Operational_documents/od-cb_index.html
NCB: Clause 3 of IECEE 02-2: National Certification BodiesCB发证机构
CBTL: clause 5 of IECEE 02-2: CB Testing Laboratories CB实验室
OP: operating procedure:http://www.iecee.org/ctl/operational/Operational_procedures.htm
CB (Certification Body) Scheme(CB架构):http://www.iecee.org/cbscheme/cbfunct.pdf
CB Bulletins CB公告板:http://members.iecee.org/iecee/ieceemembers.nsf/cb_bulletin?OpenForm (要用户名,密码)
CTL 1:http://www.iecee.org/ctl/sheet/html/ctl_decisions_index.htm
看这个为主ctl/osm:http://decisions.iecee.org/iecee/SearchCMC.nsf/de_h.xsp?v=ctl
CB安全元件接受要求:http://components.iecee.org/ (要用户名,密码)
IEC TRF: http://www.iecee.org/cbscheme/html/cbtrep.htm (要用户名,密码)
USER: Joe , password : Sep16
认证查询网站:
F Mark 网址无效
澳洲认证查询:
零部件标准清单:
List of Useful component standards (most up-to-date)(Red colour indicates recent changes –with last mod. date)
Type of component | CDF available? | Applied standard | Remarks | Last Modified date | |||||||||
AC Inlet | yes | EN 60320-1:2001
EN 60320-1:2001/A1:2007 |
EN 60320-1:1996 (incl amend A1 & A2) valid until 01.07.2004
Valid from 01.10.2010 |
15.04.2008 | |||||||||
Appliance coupler (connector on Det. Power Cord) | yes | Same as above | Same as above | — | |||||||||
Appliance Outlet/Interconnection coupler | yes | EN 60320-2-2:1998 | EN 60320-2-2:1991 expired on 01.07.2001 | 14.06.2006 | |||||||||
Ballast for Fluorescent Lamps (linear type) | yes | EN 61347-2-8:2001
EN 61347-2-8:2001+A1 |
EN 60920:1991 + Amends valid until 01.12.2006
Valid from 01.02.2009 |
15.04.2008 | |||||||||
Capacitor | yes | EN 132400:1994 +A1-A4 (IEC 60384-14:1993 mod.) / DIN EN 132400:2002 | DIN VDE 0565 Teil 1-1:1999 equivalent to the EN standard with A1-A3 valid until 01.08.2003) | ||||||||||
Capacitor (X, Y) | ?? | EN 60384-14 (IEC 60384-14 3rd Ed.) | EN 132400:1994 +amds valid until 01.07.2008 | 21.11.2006 | |||||||||
Circuit Breaker (in equipment)
Following can be used for fixed installation equipment -> |
?? | EN 60934:2001
EN 60934:2001 +A1
EN 60898-1:1991 +A1-A17+A18+A19 or EN 60898-1:2003 EN 60898-1:2003+A1:2004+A11:2005 EN 60898-2:2003 (for AC&DC operation) |
EN 60934:2001without A1 is still valid until 01.02.2010;
EN 60934:2001 Valid from 01.11.2003 EN 60898-1:1991 +Amds and EN 60898-1:2003 only valid until 01.10.2008 |
20.03.2008 | |||||||||
Connector | yes | EN 61984:2001 | Valid from 01.10.2004 | ||||||||||
DC-DC Converter | yes | EN 60950-1:2001 | Only considered for IT equipment. | 19.06.2007 | |||||||||
Electronic Transformer (converter) | yes | EN 61347-2-2:2001
EN 61347-2-2:2001+A1
EN 61347-2-2:2001+A1+A2 |
Valid from 01.12.2006
EN 61347-2-2:2001 only valid until 01.02.2009
EN 61347-2-2:2001+A1 valid until 01.06.2009 |
20.03.2008 | |||||||||
Electronic Ballast for Fluorescent Lamps | yes | EN 61347-2-3:2001
EN 61347-2-3:2001 +A1
EN 61347-2-3:2001+A1+A2 |
Valid from 01.12.2006
EN 61347-2-3:2001 only valid until 01.09.2007 (A1 only valid until 01.02.2009) EN 61347-1/A1 applies from 01.01.2011 |
15.04.2008 | |||||||||
Energy Saving Lamp | yes | EN 60968:1990 +A1 +A2 | EN 60968:1990 +A1 is no longer valid since 01.10.2002 | ||||||||||
EMI Filter (Line Filter or Mains Filter) | yes | EN 133200:1999
EN 60939-2 |
DIN VDE 0565 Teil 3-1:1996 equivalent to EN 133200:1994 valid until 27.07.2003)
EN 133200:1999 valid until 01.03.2008 |
20.03.2008 | |||||||||
Fuse (Current fuse) | yes | EN 60127-1:1991 +A1 +A2 and
EN 60127-2:2003 +A1:2003 EN 60127-3:1996 +A2:2003 |
EN 60127-2:2003 only valid until 01.03.2006
EN 60127-3:1991 expired on 01.12.2001 EN 60127-3:1996 valid until 01.02.2006 (EN 60127-1/A1 only valid until 01.02.2006) |
16.11.2006 | |||||||||
Fuseholder (for IEC 60127 fuse) | ?? | EN 60127-6:1994 +A1+A2 | EN 60127-6:1994 +A1 only valid until 01.02.2006 | 19.06.2007 | |||||||||
Lampholder (Edison Screw type) | yes | EN 60238:1998 +A1+A2 (Incl. Corr. To EN 60238/A2)
|
EN 60238:1998 valid until 01.12.2006 (EN 60238:1998 +A1 also until 01.12.2006) | 18.02.2005 | |||||||||
Lampholder (Bayonet type) | ?? | EN 61184:1997 +A1 | EN 61184:1994 +A1 valid until 01.07.2003
EN 61184:1997 until 01.12.2007 |
18.02.2005 | |||||||||
Lampholder (miscellaneous) | yes | EN 60838-1::1998 +A1 +A2 (Incl corr to EN 60838-1) | EN 60838-1:1994 +A1 expired on 01.10.1998
EN 60838-1:1998 +A1 only valid until 01.12.2006 |
18.02.2005 | |||||||||
Lampholder (Fluorescent Lamp) | ?? | EN 60400:1996 +A1+A2
EN 60400:2000 +A1 (incl. Corr. To EN 60400:2000 +A1) |
EN 60400:1992 +A1+A2 expired on 01.04.2002
EN 60400:1996 +Amds expires 01.01.2007 (EN 60400:2000 valid until 01.01.2007) |
18.02.2005 | |||||||||
Motor Capacitor | yes | EN 60252-1:2001 | EN 60252:1994 is valid until 01.10.2004 | ||||||||||
Motion Sensor / Dimmer / Touch switch / IR remote switch / Dusk switch | yes | EN 61058-1:2002 | EN 61058-1:1992 +A1 and DIN VDE 0630:1992 +DIN VDE 0630 Teil 12 are valid in parallel until 01.03.2009 | 12.04.2004 | |||||||||
Optocoupler | yes | EN 60747-5-1:2001 +A1 +A2 and EN 60747-5-2:2001+A1 and EN 60747-5-3:2001 +A1 | EN 60747-5-1:2001 +A1 / 60747-5-2 / -5-3 are valid in parallel until 01.05.2005
DIN VDE 0884:1987 is valid in parallel until 01.01.2004 |
18.02.2005 |
Plug (mains plug), class I German type | yes | DIN VDE 0620-1:2002
DIN VDE 0620-1:2005 |
DIN VDE 0620:1992 and DIN VDE 0624-1:2000 are valid in parallel until 31.12.2004
EK1 decision –existing certificates valid until 3 years from decision date 09.03.2005 |
07.06.2005 |
Plug, Class II Europlug | yes | EN 50075:1990 (DIN VDE 0620-101:1992) | Valid (there is no expiry date for DIN VDE 0620-101) | |
Power Cord (PVC) | yes | HD 21.5 S3:1994 +A1+A2 (DIN VDE 0281-5:2002) | HD 21.5 S3 and DIN VDE 0281-5:2001 valid in parallel until 01.04.2003; DIN VDE 0281-5:1995 expired on 01.08.2001 | |
Power Cord (Rubber – H07RN.. / H05RN..) | yes | HD 22.4 S3 :1995 +A1 +A2 (DIN VDE 0282-4:2003) | HD 22.4 S3 +A1 expired on 01.09.2003 | |
Power Cord (Rubber) | yes | DIN VDE 0282-4:2005 (HD22.4 S4:2004) | HD 22.4 S3 and Amds valid until 01.02.2006 | 18.02.2005 |
Relay (All or Nothing) | yes | EN 61810-1:1998 / EN 61810-5:1998 and
EN 60255-23:1996 |
EN 60255-1-00:1997 is valid until 01.08.2003. | (Bold marks the min standard to be listed) |
Relay (All or nothing) | yes | EN 61810-1:2004 (replaces EN 61810-5 and can be used without EN 60255-23) | EN 61810-1:1998 (and others above) valid until 01.12.2008 | 18.02.2005 |
Socket Outlet (in equipment) | yes | DIN VDE 0620-1:2002 | As for plug above | ||||||||
Switch (appliance switch – built-in) | yes | EN 61058-1:2002 | EN 61058-1:1992 +A1 and DIN VDE 0630:1992 are valid in parallel until 01.03.2009 | 12.04.2004 | |||||||
Switch, Cord connected | yes | EN 61058-1:2002 and EN 61058-2-1:1993 +A1 +A11 (A11 from 01.03.2009) | EN 61058-1:1992 +A1 valid in parallel as above. | 09.05.2004 | |||||||
Switch, Electronic (fixed installation) | yes | EN 60669-1:1999 + A1 and EN 60669-2-1:2000 +A2
EN 60669-2-1:2004 |
EN 60669-2-1:1996 +A11 (used with –1:1995 +A1) is valid until 01.10.2005
EN 60669-2-1:2000+A2 valid until 01.07.2009 |
18.02.2005 | |||||||
Terminal Block (screw type) | yes | EN 60998-1:1993 +A1 and EN 60998-2-1:1993
EN 60998-1:2004 and EN 60998-2-1:2004 |
EN 60998-1:1993 is valid without A1 until 01.08.2003
EN 60998-1:1993 and EN 60998-2-1:1993 valid until 01.03.2007 |
20.03.2008 | |||||||
Terminal Block (screwless) | yes | EN 60998-1:1993 +A1 and EN 60998-2-2:1993
EN 60998-1:2004 and EN 60998-2-2:2004 |
As above
As above |
15.02.2006 | |||||||
Thermal Cut-out / Thermostat | yes | EN 60730-1:2000 and EN 60730-2-9:2002
EN 60730-1:2000/A11:2002 (01.02.2009) & /A12:2003 (01.06.2010) and EN 60730-2-9:2002 +A1:2003 +A11:2003 (applies from 01.12.2008 for –2-9) EN 60730-2-9:2002 +A11+A12+A1+A2 (A2 applies from 01.12.2007) |
EN 60730-1:1995 +A1-A17 and EN 60730-2-9:1995 +A1-A12 valid in parallel until 01.12.2008;
EN 60730-2-9:1995 +A1+A11+A2 is valid until 01.01.2004 (note EN 60730-1:2000/A1:2004 is valid from 01.09.2004 but with no DOW!) |
18.02.2005
24.08.2005 |
|||||||
Thermal Fuse (Thermal link) | yes | EN 60691:1995 +A2
EN 60691:2003 |
EN 60691:1995 is valid until 01.11.2003
EN 60691:1995 +A2 is valid until 01.12.2005 |
12.04.2004 | |||||||
Thermal Motor Protector | no | EN 60730-1:2000 and EN 60730-2-2:2002 (see also above for amendments to part 1) | EN 60730-2-2:1991 + Amds is valid until 01.03.2009 | 09.05.2004 | |||||||
Timer / Electronic Timer | yes | EN 60730-1:1995 +A1-A17 and EN 60730-2-7:1991 +A11+A12+A1 (see also 60730-2-9 above for future changes to part 1)
EN 60730-2-7:1991 +A1+A11-A14 applies from 01.06.2010 |
EN 60730-2-7:1991 is valid until 01.01.2004
EN 60730-2-7:1991 +A1+A11-A12 is valid until 01.03.2006 |
18.02.2005 | |||||||
Transformer (Safety Isolating) | yes | EN 61558-1:1997 +A1+A11 and EN 61558-2-6:1997 | EN 60742:1995 has expired for these transformers on 01.08.2001
EN 61558-1 without A11 valid until 01.12.2005. |
12.04.2004 | |||||||
Transformer (for Toy) | yes | EN 61558-1:1997 +A1 +A11 and EN 61558-2-7:1997 +A11 | EN 60742:1995 has expired for these transformers on 01.08.2001
EN 61558-1 without A11 as above EN 61558-2-7 without A11 valid until 01.09.2005 |
18.02.2005 | |||||||
Varistor | yes | CECC 42200 and CECC 42100 or IEC 61051-1 / 61051-2 | UL certification acceptable for across the mains after fuse (See OSM decision) |